{"product_id":"auto-apc-easy-ups-srv-srvpm6kril-ups-rack-mountable-ac-220-230-240-v-6000-watt-6000-va-no-battery-rs-232-usb","title":"APC Easy UPS On-Line, 6kVA\/6kW, Rackmount 2U, 230V, 1x Hard wire 3-wire(1P+N+E) outlet, Intelligent Slot, Extended runtime, No battery, W\/O rail kit, Double-conversion (Online), 6 kVA, 6000 W, Sine, 40\/70 Hz, 220 V","description":"APC Easy UPS On-Line, 6kVA\/6kW, Rackmount 2U, 230V, 1x Hard wire 3-wire(1P+N+E) outlet, Intelligent Slot, Extended runtime, No battery, W\/O rail kit. UPS topology: Double-conversion (Online), Output power capacity: 6 kVA, Output power: 6000 W. AC outlet types: Hard Wire 3-wire (1PH + N + G), Power plug: Terminal, USB port type: USB Type-B. Battery technology: Sealed Lead Acid (VRLA), Battery recharge time: 3 h. Form factor: Rackmount, Product colour: Black, Rack capacity: 2U. Compliance certificates: RoHS, REACH, WEEE, Certification: CE; EAC\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eDouble-conversion (Online)\u003c\/li\u003e\n\u003cli\u003e6 kVA 6000 W\u003c\/li\u003e\n\u003cli\u003eWaveform: Sine\u003c\/li\u003e\n\u003cli\u003eSealed Lead Acid (VRLA)\u003c\/li\u003e\n\u003cli\u003eRackmount Black\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003ctable style=\"width: 100%; display: block;\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The two main UPS topologies are Double-Conversion True Online and Standby \/ Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.\"\u003e\n\u003ctd\u003eUPS topology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion (Online)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum power that the device can produce.\"\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e6 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The power that the device can produce.\"\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e6000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).\"\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The frequency (Hz) which is required to power the product.\"\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40\/70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The minumum voltage produced by the device during operation.\"\u003e\n\u003ctd\u003eOutput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum output voltage produced by the device.\"\u003e\n\u003ctd\u003eOutput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.\"\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e600 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).\"\u003e\n\u003ctd\u003eNumber of input phases\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).\"\u003e\n\u003ctd\u003eNumber of output phases\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The nominal AC voltage levels that the device can accept as a single-phase power source, measured in V (e.g. 230).\"\u003e\n\u003ctd\u003eSingle-phase input voltage supported\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).\"\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device features an energy-saving mode to reduce power consumption during operation.\"\u003e\n\u003ctd\u003eECO mode\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.\"\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Alarms that make a sound when they are activated (set off).\"\u003e\n\u003ctd\u003eAudible alarm(s)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The specific conditions or system states that trigger an audible warning signal, such as a low battery or an overload event.\"\u003e\n\u003ctd\u003eAudible alarm modes\u003c\/td\u003e\n\u003ctd\u003eAlarm when on battery, Low battery alarm, Overload alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device automatically reboots itself after a power failure or a system crash.\"\u003e\n\u003ctd\u003eAuto-restart\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the product requires no regular servicing or upkeep during its operational life.\"\u003e\n\u003ctd\u003eMaintenance-free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePorts \u0026amp; interfaces\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type of outlet for AC electricity.\"\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eHard Wire 3-wire (1PH + N + G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.\"\u003e\n\u003ctd\u003ePower plug\u003c\/td\u003e\n\u003ctd\u003eTerminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The device features a socket into which a USB cable can be plugged.\"\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Number of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called \" hi-speed adding higher maximum signaling rate of mbit throughput up to mb or usb ports are usually black.\u003e\n\u003ctd\u003eUSB 2.0 ports quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The physical interface standard of the USB connector used for connectivity or charging (e.g. USB-C).\"\u003e\n\u003ctd\u003eUSB port type\u003c\/td\u003e\n\u003ctd\u003eUSB Type-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device features a serial port for communication and management purposes.\"\u003e\n\u003ctd\u003eSerial interface\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term \" serial port usually identifies hardware more or less compliant to the rs-232 standard intended interface with a modem similar communication device. in modern computers and peripherals ports have largely been replaced by usbs other interfaces.\u003e\n\u003ctd\u003eSerial ports quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device has a dedicated port to remotely shut down the unit in the event of an emergency.\"\u003e\n\u003ctd\u003eEmergency Power Off (EPO) connector\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the unit features a dedicated expansion slot for installing optional network management or communication cards.\"\u003e\n\u003ctd\u003eSmartSlot\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBattery\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type of battery in the device, e.g. nickel–cadmium (NiCd).\"\u003e\n\u003ctd\u003eBattery technology\u003c\/td\u003e\n\u003ctd\u003eSealed Lead Acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Approximate time required to recharge the battery from completely empty to completely full\"\u003e\n\u003ctd\u003eBattery recharge time\u003c\/td\u003e\n\u003ctd\u003e3 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device automatically performs periodic tests to verify the health and charge level of the battery.\"\u003e\n\u003ctd\u003eAutomatic battery test\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDesign\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The shape or design of the product.\"\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eRackmount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The spase that device fill in rack.\"\u003e\n\u003ctd\u003eRack capacity\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The colour e.g. red, blue, green, black, white.\"\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Type of display (screen) e.g. LCD.\"\u003e\n\u003ctd\u003eDisplay type\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).\"\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperational conditions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The minimum and maximum temperatures at which the product can be safely operated.\"\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.\"\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.\"\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum and minimum height above sea level at which the device can function correctly, measured in m.\"\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.\"\u003e\n\u003ctd\u003eNon-operating altitude\u003c\/td\u003e\n\u003ctd\u003e0 - 14763.6 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTechnical details\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the product is delivered in packaging made from environmentally friendly or recycled materials.\"\u003e\n\u003ctd\u003eSustainable packaging\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Identifies which specific recycled or secondary material types are present in the packaging.\"\u003e\n\u003ctd\u003ePackaging recycled materials\u003c\/td\u003e\n\u003ctd\u003eRecycled cardboard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The recommended orientation or location for installing the unit to ensure optimal performance and stability (e.g. wall, ceiling, or desk).\"\u003e\n\u003ctd\u003ePreferred mounting position\u003c\/td\u003e\n\u003ctd\u003elower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Take-back system allow consumers to return used products to manufacturers or retailers for reuse, recycling, or responsible disposal.\"\u003e\n\u003ctd\u003eTake-back system\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the product is delivered in packaging that does not contain any single-use plastics.\"\u003e\n\u003ctd\u003ePackaging without single use plastic\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCertificates\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the product complies with the Waste Electrical and Electronic Equipment (WEEE) directive regarding the disposal and recycling of electronic waste.\"\u003e\n\u003ctd\u003eWaste Electrical and Electronic Equipment (WEEE) compliance\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.\"\u003e\n\u003ctd\u003eCompliance certificates\u003c\/td\u003e\n\u003ctd\u003eRoHS, REACH, WEEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Specifies the official standards, safety approvals, or regulatory certifications the product has received.\"\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE; EAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePackaging content\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Specifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).\"\u003e\n\u003ctd\u003eCables included\u003c\/td\u003e\n\u003ctd\u003eUSB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether a printed user manual is included in the package.\"\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeight \u0026amp; dimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The measurement or extent of something from side to side.\"\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e438 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The distance from the front to the back of something.\"\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e615 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The measurement of the product from head to foot or from base to top.\"\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e86.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and\/or supplies.\"\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePackaging data\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the product is supplied with software on a compact disc.\"\u003e\n\u003ctd\u003eSoftware CD\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The distance from one side of the packaging to the other.\"\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The distance from the front to the back of the packaging.\"\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e760 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The distance from the top to the bottom of the packaging.\"\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Weight of the packaged product.\"\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLogistics data\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The integrated Tariff of the European Union code used to identify the product for customs and trade purposes.\"\u003e\n\u003ctd\u003eCustoms product code (TARIC)\u003c\/td\u003e\n\u003ctd\u003e8504409590\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The standardized numerical method of classifying traded products used by customs authorities around the world to identify goods for tariffs and statistics.\"\u003e\n\u003ctd\u003eHarmonized System (HS) code\u003c\/td\u003e\n\u003ctd\u003e85078000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation \/ logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.\"\u003e\n\u003ctd\u003eTotal carbon footprint (kg of CO2e)\u003c\/td\u003e\n\u003ctd\u003e3557.503130030406\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Country where the device is made. Aka Country of manufacture (COM).\"\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOther features\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The voltage which the manufacturer states that the device can produce.\"\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The voltage which the manufacturer recommends that the device needs to operate normally.\"\u003e\n\u003ctd\u003eNominal input voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type of connection used for outputs from this device e.g. USB.\"\u003e\n\u003ctd\u003eOutput connection type\u003c\/td\u003e\n\u003ctd\u003ehard wire 3-wire (1P + N + E) for 1 zone(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The electrical potential difference delivered by the device, typically expressed in volts (e.g. 24-48).\"\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"What size the mounting head of the product is, to couple it with a camera.\"\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003efront; horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":67956208435243,"sku":"4977124","price":2180.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/2408\/0171\/files\/36c33096c8156052dac074cee39794e5f0d5753c.jpg?v=1792555385","url":"https:\/\/store.itcode.co.uk\/products\/auto-apc-easy-ups-srv-srvpm6kril-ups-rack-mountable-ac-220-230-240-v-6000-watt-6000-va-no-battery-rs-232-usb","provider":"IT Code Store","version":"1.0","type":"link"}