{"product_id":"auto-d-link-dgs-1520-52mp-switch-l3-smart-44-x-10-100-1000-poe-4-x-2-5gbase-t-poe-2-x-10-gigabit-ethernet-2-x-10-gigabit-sfp-rack-mountable-poe-370-w","title":"D-Link 48-Port Gigabit Stackable POE+ Smart Managed Switch with 2 x 10GBase-T \u0026 2 x 10G SFP+, Managed, L3, Gigabit Ethernet (10\/100\/1000), Power over Ethernet (PoE), Rack mounting, 1U","description":"D-Link 48-Port Gigabit Stackable POE+ Smart Managed Switch with 2 x 10GBase-T \u0026amp; 2 x 10G SFP+. Switch type: Managed, Switch layer: L3. Basic switching RJ-45 Ethernet ports type: Gigabit Ethernet (10\/100\/1000), Basic switching RJ-45 Ethernet ports quantity: 44. MAC address table: 16384 entries, Switching capacity: 188 Gbit\/s. Networking standards: IEEE 802.3, IEEE 802.3ab, IEEE 802.3ae, IEEE 802.3af, IEEE 802.3at, IEEE 802.3az, IEEE 802.3bz,.... Power over Ethernet (PoE). Rack mounting, Form factor: 1U\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eManaged L3 Web-based management\u003c\/li\u003e\n\u003cli\u003eBasic switching RJ-45 Ethernet ports quantity: 44\u003c\/li\u003e\n\u003cli\u003e10G support 10BASE-T, 100BASE-FX, 100BASE-TX, 1000BASE-T\u003c\/li\u003e\n\u003cli\u003eMAC address table: 16384 entries Switching capacity: 188 Gbit\/s\u003c\/li\u003e\n\u003cli\u003e1U Rack mounting Stackable\u003c\/li\u003e\n\u003cli\u003eAC Power over Ethernet (PoE)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003ctable style=\"width: 100%; display: block;\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManagement features\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"What switch device has, managed or unmanaged.\"\u003e\n\u003ctd\u003eSwitch type\u003c\/td\u003e\n\u003ctd\u003eManaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"A network switch is a computer networking device that links networking segments. A switch has different layers, such as layer 2 (a network bridge, operating at the data link layer, interconnecting a small number of devices) and layer 4 (can act as a firewall, amongst other things).\"\u003e\n\u003ctd\u003eSwitch layer\u003c\/td\u003e\n\u003ctd\u003eL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Using a website\/web application to manage something.\"\u003e\n\u003ctd\u003eWeb-based management\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePorts \u0026amp; interfaces\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of basic switching RJ-45 Ethernet ports (sockets).\"\u003e\n\u003ctd\u003eBasic switching RJ-45 Ethernet ports quantity\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type\/category of basic switching RJ-45 Ethernet ports (sockets).\"\u003e\n\u003ctd\u003eBasic switching RJ-45 Ethernet ports type\u003c\/td\u003e\n\u003ctd\u003eGigabit Ethernet (10\/100\/1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The total number of copper-based Ethernet ports supporting data transfer speeds up to 2.5 Gbps.\"\u003e\n\u003ctd\u003e2.5G Ethernet (copper) ports quantity\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of 10 Gigabit Ethernet ports that utilize copper cabling (RJ45) for network connectivity.\"\u003e\n\u003ctd\u003e10G Ethernet (copper) ports quantity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The total number of available slots for inserting SFP+ transceiver modules to provide high-speed fiber optic or copper connectivity.\"\u003e\n\u003ctd\u003eSFP+ module slots quantity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of sockets (ports) for fibers (cables).\"\u003e\n\u003ctd\u003eFiber ports quantity\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"This terminates the end of an optical fiber, and enables quicker connection and disconnection than splicing. The connectors mechanically couple and align the cores of fibers so light can pass. Better connectors lose very little light due to reflection or misalignment of the fibers. In all there have been about 100 types of optic fiber connectors produced.\"\u003e\n\u003ctd\u003eFiber optic connector\u003c\/td\u003e\n\u003ctd\u003eSFP+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eNetwork\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The way in which the network is working, e.g. IEEE 802.11a, IEEE 802.11b, IEEE 802.11g.\"\u003e\n\u003ctd\u003eNetworking standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3, IEEE 802.3ab, IEEE 802.3ae, IEEE 802.3af, IEEE 802.3at, IEEE 802.3az, IEEE 802.3bz, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The product can use Oracle 10G, which is a database management system introduced in 2003.\"\u003e\n\u003ctd\u003e10G support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The specific standard used for data transmission over copper twisted-pair cables (e.g., 1000BASE-T).\"\u003e\n\u003ctd\u003eCopper ethernet cabling technology\u003c\/td\u003e\n\u003ctd\u003e10BASE-T, 100BASE-FX, 100BASE-TX, 1000BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports the management of data transmission rates to prevent buffer overflow.\"\u003e\n\u003ctd\u003eFlow control support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports combining multiple network connections into a single logical link to increase throughput and provide redundancy.\"\u003e\n\u003ctd\u003eLink aggregation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"A Medium Dependent Interface (MDI) describes the interface (both physical and electrical) in a computer network from a physical layer implementation to the physical medium used to carry the transmission. Ethernet over twisted pair also defines a medium dependent interface crossover (MDIX) interface. Auto-MDIX ports on newer network interfaces detect if the connection would require a crossover, and automatically chooses the MDI or MDIX configuration to properly match the other end of the link.\"\u003e\n\u003ctd\u003eAuto MDI\/MDI-X\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports a network protocol that prevents loops in a bridge network topology.\"\u003e\n\u003ctd\u003eSpanning tree protocol\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device is susceptible to a performance degradation where a queue is blocked by a packet at the front of the line.\"\u003e\n\u003ctd\u003eHead-of-line (HOL) blocking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"A Virtual Local Area Network (VLAN) consists of a group of computers and switches that can be physically distributed over different networks and buildings, but form one LAN on a logical level.\"\u003e\n\u003ctd\u003eVLAN support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eData transmission\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The data transfer capacity of the switch per second.\"\u003e\n\u003ctd\u003eSwitching capacity\u003c\/td\u003e\n\u003ctd\u003e188 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of packets the device can process and send per second, measured in millions of packets per second (e.g., 148.8 Mpps).\"\u003e\n\u003ctd\u003eForwarding rate\u003c\/td\u003e\n\u003ctd\u003e139.88 Mpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The MAC address is the \" media access control address it is a unique given to network interface controller in device. mac table shows the addresses format.\u003e\n\u003ctd\u003eMAC address table\u003c\/td\u003e\n\u003ctd\u003e16384 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device buffers the entire incoming packet to verify its integrity before forwarding it to the destination.\"\u003e\n\u003ctd\u003eStore-and-forward\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device allows the manual configuration of fixed paths for network traffic to specific destinations.\"\u003e\n\u003ctd\u003eStatic route\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports Ethernet frames with a payload larger than the standard 1500 bytes to increase data transfer efficiency.\"\u003e\n\u003ctd\u003eJumbo frames support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates the support for Ethernet frames larger than the standard 1500 bytes to increase data transfer efficiency (e.g. 9000 bytes).\"\u003e\n\u003ctd\u003eJumbo frames\u003c\/td\u003e\n\u003ctd\u003e12288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSecurity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Specifies the supported Dynamic Host Configuration Protocol (DHCP) options for network configuration, such as DHCP Option 66 for boot server addresses.\"\u003e\n\u003ctd\u003eDHCP features\u003c\/td\u003e\n\u003ctd\u003eDHCP snooping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device can optimize multicast traffic by ensuring it is only forwarded to the ports that have requested it.\"\u003e\n\u003ctd\u003eIGMP snooping\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device has a mechanism to detect and prevent network loops to avoid broadcast storms.\"\u003e\n\u003ctd\u003eLoop protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports Bridge Protocol Data Unit (BPDU) filtering or protection to prevent network loops and enhance security.\"\u003e\n\u003ctd\u003eBPDU filtering\/protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Specifies the method used to populate the address table, such as through manual configuration (static), automatic learning (dynamic), or traffic discarding (blackhole).\"\u003e\n\u003ctd\u003eMAC address entries\u003c\/td\u003e\n\u003ctd\u003eStatic MAC address entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMulticast features\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device can monitor MLD messages to optimize the delivery of multicast traffic by ensuring it is only forwarded to ports that have requested it.\"\u003e\n\u003ctd\u003eMulticast Listener Discovery (MLD) snooping\u003c\/td\u003e\n\u003ctd\u003ev1\/v2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProtocols\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports the GARP VLAN Registration Protocol (GVRP) for the automatic distribution of VLAN configuration.\"\u003e\n\u003ctd\u003eGARP VLAN Registration Protocol (GVRP)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The set of standardized rules used by the device to determine the best path for data packets across a network (e.g. BGP, OSPF, RIP).\"\u003e\n\u003ctd\u003eRouting protocols\u003c\/td\u003e\n\u003ctd\u003eOSPF, RIP, RIPng, VRRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDesign\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type of mounting that can position devices in a shelving system (rack).\"\u003e\n\u003ctd\u003eRack mounting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Devices can be placed on top of each other.\"\u003e\n\u003ctd\u003eStackable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The shape or design of the product.\"\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The colour e.g. red, blue, green, black, white.\"\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).\"\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003ctd\u003eActivity, Link, Power, Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePerformance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum number of individual devices that can be connected together to operate as a single logical unit.\"\u003e\n\u003ctd\u003ePhysical stacking (units)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum number of physical devices that can be logically grouped together to be managed as a single entity.\"\u003e\n\u003ctd\u003eVirtual stacking (units)\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The amplitude level of the undesired background noise, usually measured in decibels (db).\"\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e56.7 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Statistical model used to indicate product\/mechanism reliability; expressed in hours and percentage of duty cycle. This number (in hours) does not indicate the mean time before failure for a single unit\/mechanism.\"\u003e\n\u003ctd\u003eMean time between failures (MTBF)\u003c\/td\u003e\n\u003ctd\u003e328174 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"What is providing power for the product e.g. mains electricity.\"\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The voltage of the AC electricity that is inputted into the product.\"\u003e\n\u003ctd\u003eAC input voltage\u003c\/td\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum amount of power used by the device.\"\u003e\n\u003ctd\u003ePower consumption (max)\u003c\/td\u003e\n\u003ctd\u003e459.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower over Ethernet (PoE)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The device supports Power over Ethernet (PoE), which is one of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras.\"\u003e\n\u003ctd\u003ePower over Ethernet (PoE)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of network ports on the switch that can provide power to connected devices using the PoE+ standard.\"\u003e\n\u003ctd\u003ePower over Ethernet plus (PoE+) ports quantity\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum total amount of power available to be distributed across all PoE-enabled ports, measured in Watts (e.g. 120W).\"\u003e\n\u003ctd\u003eTotal Power over Ethernet (PoE) budget\u003c\/td\u003e\n\u003ctd\u003e370 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperational conditions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The minimum and maximum temperatures at which the product can be safely operated.\"\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-5 - 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The minimum and maximum temperatures at which the product can be safely stored.\"\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-40 - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.\"\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e10 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.\"\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The heat generated by the power supply.\"\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e1635.1 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeight \u0026amp; dimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The measurement or extent of something from side to side.\"\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e441 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The distance from the front to the back of something.\"\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e308.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The measurement of the product from head to foot or from base to top.\"\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and\/or supplies.\"\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCertificates\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Specifies the official standards, safety approvals, or regulatory certifications the product has received.\"\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE Class A, FCC Class A, IC Class A, RCM Class A, VCCI Class A, BSMI Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLogistics data\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The standardized numerical method of classifying traded products used by customs authorities around the world to identify goods for tariffs and statistics.\"\u003e\n\u003ctd\u003eHarmonized System (HS) code\u003c\/td\u003e\n\u003ctd\u003e85176990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"D-Link","offers":[{"title":"Default Title","offer_id":67983894118443,"sku":"6183383","price":912.58,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/2408\/0171\/files\/5f2635f2021372e1288e4409625328730cc508ed.jpg?v=1792724028","url":"https:\/\/store.itcode.co.uk\/products\/auto-d-link-dgs-1520-52mp-switch-l3-smart-44-x-10-100-1000-poe-4-x-2-5gbase-t-poe-2-x-10-gigabit-ethernet-2-x-10-gigabit-sfp-rack-mountable-poe-370-w","provider":"IT Code Store","version":"1.0","type":"link"}