{"product_id":"auto-eaton-9px-9px5kirtn-ups-rack-mountable-external-ac-200-208-220-230-240-v-4500-watt-5000-va-ethernet-10-100-1000-rs-232-usb-pfc-3u-19","title":"Eaton 9PX5KIRTN, Double-conversion (Online), 5 kVA, 4500 W, Pure sine, 176 V, 276 V","description":"Eaton 9PX5KIRTN. UPS topology: Double-conversion (Online), Output power capacity: 5 kVA, Output power: 4500 W. AC outlet types: C13 coupler, C19 coupler, Terminal, Power plug: Terminal, AC outlets quantity: 11 AC outlet(s). Battery technology: Sealed Lead Acid (VRLA), Typical backup time at half load: 13 min. Form factor: Rackmount\/Tower, Product colour: Black, Rack capacity: 3U. Certification: IEC\/EN 62040-1, UL 1778, IEC\/EN 62040 -2, FCC Class A, IEC\/EN 62040-3 (Performance), CE, CB report...\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eDouble-conversion (Online)\u003c\/li\u003e\n\u003cli\u003e5 kVA 4500 W\u003c\/li\u003e\n\u003cli\u003eWaveform: Pure sine\u003c\/li\u003e\n\u003cli\u003e11 AC outlet(s)\u003c\/li\u003e\n\u003cli\u003eSealed Lead Acid (VRLA)\u003c\/li\u003e\n\u003cli\u003eRackmount\/Tower Black\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003ctable style=\"width: 100%; display: block;\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The two main UPS topologies are Double-Conversion True Online and Standby \/ Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.\"\u003e\n\u003ctd\u003eUPS topology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion (Online)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum power that the device can produce.\"\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e5 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The power that the device can produce.\"\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e4500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).\"\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The minumum voltage needed by the device during operation.\"\u003e\n\u003ctd\u003eInput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e176 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The  maximum input voltage supported by the device.\"\u003e\n\u003ctd\u003eInput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e276 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The frequency (Hz) which is required to power the product.\"\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40\/70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The minumum voltage produced by the device during operation.\"\u003e\n\u003ctd\u003eOutput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum output voltage produced by the device.\"\u003e\n\u003ctd\u003eOutput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The frequency of the electrical current delivered by the device, measured in hertz (e.g. 47\/53 Hz).\"\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).\"\u003e\n\u003ctd\u003eNumber of input phases\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).\"\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e94%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The ratio of the real power consumed by the device to the apparent power supplied to it, expressed as a value between 0 and 1.\"\u003e\n\u003ctd\u003ePower factor\u003c\/td\u003e\n\u003ctd\u003e0.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).\"\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.\"\u003e\n\u003ctd\u003eOutput voltage Total Harmonic Distortion (THD)\u003c\/td\u003e\n\u003ctd\u003e2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The degree of harmonic distortion present in the input current, expressed as a percentage (%).\"\u003e\n\u003ctd\u003eInput current Total Harmonic Distortion (THD)\u003c\/td\u003e\n\u003ctd\u003e5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The amplitude level of the undesired background noise, usually measured in decibels (db).\"\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e45 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePorts \u0026amp; interfaces\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type of outlet for AC electricity.\"\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eC13 coupler, C19 coupler, Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.\"\u003e\n\u003ctd\u003ePower plug\u003c\/td\u003e\n\u003ctd\u003eTerminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of sockets in the device where AC electrical power can be connected.\"\u003e\n\u003ctd\u003eAC outlets quantity\u003c\/td\u003e\n\u003ctd\u003e11 AC outlet(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The device features a socket into which a USB cable can be plugged.\"\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Number of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called \" hi-speed adding higher maximum signaling rate of mbit throughput up to mb or usb ports are usually black.\u003e\n\u003ctd\u003eUSB 2.0 ports quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.\"\u003e\n\u003ctd\u003eRS-232 ports\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBattery\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type of battery in the device, e.g. nickel–cadmium (NiCd).\"\u003e\n\u003ctd\u003eBattery technology\u003c\/td\u003e\n\u003ctd\u003eSealed Lead Acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).\"\u003e\n\u003ctd\u003eTypical backup time at half load\u003c\/td\u003e\n\u003ctd\u003e13 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the battery can be replaced while the unit remains powered on and operational.\"\u003e\n\u003ctd\u003eHot-swap battery\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device automatically performs periodic tests to verify the health and charge level of the battery.\"\u003e\n\u003ctd\u003eAutomatic battery test\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDesign\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The shape or design of the product.\"\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eRackmount\/Tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The spase that device fill in rack.\"\u003e\n\u003ctd\u003eRack capacity\u003c\/td\u003e\n\u003ctd\u003e3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The colour e.g. red, blue, green, black, white.\"\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Type of display (screen) e.g. LCD.\"\u003e\n\u003ctd\u003eDisplay type\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).\"\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperational conditions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The minimum and maximum temperatures at which the product can be safely operated.\"\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCertificates\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Specifies the official standards, safety approvals, or regulatory certifications the product has received.\"\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 62040-1, UL 1778, IEC\/EN 62040 -2, FCC Class A, IEC\/EN 62040-3 (Performance), CE, CB report (TUV), UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePackaging content\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.\"\u003e\n\u003ctd\u003eRack mount kit\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether a dedicated network management card for remote monitoring and control is included with the unit.\"\u003e\n\u003ctd\u003eManagement card included\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSafety regulation \u0026amp; standards\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"List of regulatory safety standards for all countries in which this product has been certified.\"\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 62040-1, UL 1778\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSustainability\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The environmental or ethical certifications the product has received to verify its sustainability standards (e.g., ASC or ACT Organic).\"\u003e\n\u003ctd\u003eSustainability certificates\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeight \u0026amp; dimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The measurement or extent of something from side to side.\"\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e440 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The distance from the front to the back of something.\"\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e685 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The measurement of the product from head to foot or from base to top.\"\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and\/or supplies.\"\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePackaging data\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Software distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.\"\u003e\n\u003ctd\u003eBundled software\u003c\/td\u003e\n\u003ctd\u003eIntelligent Power Software suite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLogistics data\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The standardized numerical method of classifying traded products used by customs authorities around the world to identify goods for tariffs and statistics.\"\u003e\n\u003ctd\u003eHarmonized System (HS) code\u003c\/td\u003e\n\u003ctd\u003e85078000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOther features\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Interface ports to connect pieces of equipment. USB (Universal Serial Bus) has become the most popular wired interface to connect peripherals. USB 2.0 supports speeds up to 480 Mbit\/s (USB 1: 12 Mbit\/s). The interface FireWire is also known as the IEEE 1394 standard. Enhanced IDE (EIDE)is sometimes referred to as Fast ATA, Fast IDE or ATA-2.\"\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The voltage which the manufacturer states that the device can produce.\"\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The voltage which the manufacturer recommends that the device needs to operate normally.\"\u003e\n\u003ctd\u003eNominal input voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":67956128415787,"sku":"2575222","price":3622.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/2408\/0171\/files\/bae30fc265a9cc8168b188128e26b9013a9b9d72.jpg?v=1792554081","url":"https:\/\/store.itcode.co.uk\/products\/auto-eaton-9px-9px5kirtn-ups-rack-mountable-external-ac-200-208-220-230-240-v-4500-watt-5000-va-ethernet-10-100-1000-rs-232-usb-pfc-3u-19","provider":"IT Code Store","version":"1.0","type":"link"}