{"product_id":"auto-eaton-9px-g2-ups-rack-mountable-external-ac-200-240-v-6000-watt-6000-va-rs-232-usb-ethernet-3u","title":"Eaton 9PX6KIRTNG2-L, Double-conversion (Online), 6 kVA, 6000 W, Pure sine, 176 V, 276 V","description":"Eaton 9PX6KIRTNG2-L. UPS topology: Double-conversion (Online), Output power capacity: 6 kVA, Output power: 6000 W. AC outlet types: C13 coupler, C39 coupler, Hardwire, Power plug: Hardwire, Serial interface type: RS-232. Battery capacity: 6000 mAh, Battery technology: Lithium-Ion (Li-Ion), Battery capacity: 6 Ah. Form factor: Rackmount\/Tower, Product colour: Black, Silver, Rack capacity: 3U. Compliance certificates: CE, cULus, UKCA, RCM, Certification: IEC\/EN 62040-1 IEC\/EN 62040-2 IEC\/EN 62040-3 ENERGY STAR certified CE cULus UKCA Cm Ukr RCM\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eDouble-conversion (Online)\u003c\/li\u003e\n\u003cli\u003e6 kVA 6000 W\u003c\/li\u003e\n\u003cli\u003eWaveform: Pure sine\u003c\/li\u003e\n\u003cli\u003eLithium-Ion (Li-Ion) 6 Ah\u003c\/li\u003e\n\u003cli\u003eRackmount\/Tower Black, Silver\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003ctable style=\"width: 100%; display: block;\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The two main UPS topologies are Double-Conversion True Online and Standby \/ Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.\"\u003e\n\u003ctd\u003eUPS topology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion (Online)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum power that the device can produce.\"\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e6 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The power that the device can produce.\"\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e6000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).\"\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003ePure sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The minumum voltage needed by the device during operation.\"\u003e\n\u003ctd\u003eInput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e176 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The  maximum input voltage supported by the device.\"\u003e\n\u003ctd\u003eInput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e276 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The frequency (Hz) which is required to power the product.\"\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e40\/70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The minumum voltage produced by the device during operation.\"\u003e\n\u003ctd\u003eOutput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum output voltage produced by the device.\"\u003e\n\u003ctd\u003eOutput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The frequency of the electrical current delivered by the device, measured in hertz (e.g. 47\/53 Hz).\"\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).\"\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e96.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The ratio of the real power delivered to the load to the apparent power supplied by the device.\"\u003e\n\u003ctd\u003eOutput power factor\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.\"\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The amplitude level of the undesired background noise, usually measured in decibels (db).\"\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e40 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePorts \u0026amp; interfaces\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type of outlet for AC electricity.\"\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eC13 coupler, C39 coupler, Hardwire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.\"\u003e\n\u003ctd\u003ePower plug\u003c\/td\u003e\n\u003ctd\u003eHardwire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The total quantity of IEC-standard jumper cables provided for connecting the unit to other devices.\"\u003e\n\u003ctd\u003eNumber of output IEC jumpers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The device features a socket into which a USB cable can be plugged.\"\u003e\n\u003ctd\u003eUSB port\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device features a serial port for communication and management purposes.\"\u003e\n\u003ctd\u003eSerial interface\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).\"\u003e\n\u003ctd\u003eSerial interface type\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term \" serial port usually identifies hardware more or less compliant to the rs-232 standard intended interface with a modem similar communication device. in modern computers and peripherals ports have largely been replaced by usbs other interfaces.\u003e\n\u003ctd\u003eSerial ports quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.\"\u003e\n\u003ctd\u003eRS-232 ports\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the unit has a dedicated expansion slot for installing a network management card.\"\u003e\n\u003ctd\u003eNetwork card slot\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device has a dedicated port to remotely shut down the unit in the event of an emergency.\"\u003e\n\u003ctd\u003eEmergency Power Off (EPO) connector\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBattery\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"A measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.\"\u003e\n\u003ctd\u003eBattery capacity\u003c\/td\u003e\n\u003ctd\u003e6000 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type of battery in the device, e.g. nickel–cadmium (NiCd).\"\u003e\n\u003ctd\u003eBattery technology\u003c\/td\u003e\n\u003ctd\u003eLithium-Ion (Li-Ion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The amount of electric charge a battery can deliver at the rated voltage. The more electrode material contained in the cell the greater its capacity. A small cell has less capacity than a larger cell with the same chemistry, although they develop the same open-circuit voltage. Capacity is measured in units such as amp-hour (A·h).\"\u003e\n\u003ctd\u003eBattery capacity\u003c\/td\u003e\n\u003ctd\u003e6 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDesign\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The shape or design of the product.\"\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eRackmount\/Tower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The spase that device fill in rack.\"\u003e\n\u003ctd\u003eRack capacity\u003c\/td\u003e\n\u003ctd\u003e3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The colour e.g. red, blue, green, black, white.\"\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack, Silver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The way in which the device is controlled.\"\u003e\n\u003ctd\u003eControl type\u003c\/td\u003e\n\u003ctd\u003eButtons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Type of display (screen) e.g. LCD.\"\u003e\n\u003ctd\u003eDisplay type\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperational conditions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The minimum and maximum temperatures at which the product can be safely operated.\"\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.\"\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCertificates\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.\"\u003e\n\u003ctd\u003eCompliance certificates\u003c\/td\u003e\n\u003ctd\u003eCE, cULus, UKCA, RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Specifies the official standards, safety approvals, or regulatory certifications the product has received.\"\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 62040-1 IEC\/EN 62040-2 IEC\/EN 62040-3 ENERGY STAR certified CE cULus UKCA Cm Ukr RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePackaging content\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the required batteries are supplied with the product.\"\u003e\n\u003ctd\u003eBatteries included\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the necessary hardware is included to install the unit into a standard 19-inch equipment rack.\"\u003e\n\u003ctd\u003eRack mount kit\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether a dedicated network management card for remote monitoring and control is included with the unit.\"\u003e\n\u003ctd\u003eManagement card included\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether a simplified, fast-start manual is included with the product.\"\u003e\n\u003ctd\u003eQuick installation guide\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSustainability\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The environmental or ethical certifications the product has received to verify its sustainability standards (e.g., ASC or ACT Organic).\"\u003e\n\u003ctd\u003eSustainability certificates\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeight \u0026amp; dimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The measurement or extent of something from side to side.\"\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e440 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The distance from the front to the back of something.\"\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e684 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The measurement of the product from head to foot or from base to top.\"\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and\/or supplies.\"\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePackaging data\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Software distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.\"\u003e\n\u003ctd\u003eBundled software\u003c\/td\u003e\n\u003ctd\u003eEaton Brlightlayer Software suite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLogistics data\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The length of time the manufacturer guarantees the product against defects, typically expressed in months or years.\"\u003e\n\u003ctd\u003eWarranty period\u003c\/td\u003e\n\u003ctd\u003e5 year(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOther features\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The voltage which the manufacturer states that the device can produce.\"\u003e\n\u003ctd\u003eNominal output voltage\u003c\/td\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"EATON","offers":[{"title":"Default Title","offer_id":67956357824555,"sku":"13112708","price":6211.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/2408\/0171\/files\/fa59ed5f8e5b68ef7642adedb76b886117d10e8b.jpg?v=1792565172","url":"https:\/\/store.itcode.co.uk\/products\/auto-eaton-9px-g2-ups-rack-mountable-external-ac-200-240-v-6000-watt-6000-va-rs-232-usb-ethernet-3u","provider":"IT Code Store","version":"1.0","type":"link"}