{"product_id":"auto-tp-link-omada-sg3428xmpp-v1-8-switch-l2-managed-16-x-10-100-1000-poe-8-x-10-100-1000-poe-4-x-10gb-ethernet-sfp-rack-mountable-poe-500-w","title":"TP-Link Omada SG3428XMPP, Managed, L2+, Gigabit Ethernet (10\/100\/1000), Power over Ethernet (PoE), Rack mounting, 1U","description":"TP-Link Omada SG3428XMPP. Switch type: Managed, Switch layer: L2+. Basic switching RJ-45 Ethernet ports type: Gigabit Ethernet (10\/100\/1000), Basic switching RJ-45 Ethernet ports quantity: 24, Console port: RJ-45\/Micro-USB. MAC address table: 16000 entries, Switching capacity: 128 Gbit\/s. Networking standards: IEEE 802.3af, IEEE 802.3at. Power connector: AC-in jack. Power over Ethernet (PoE). Rack mounting, Form factor: 1U\u003cbr\u003e\u003cul\u003e\n\u003cli\u003eManaged L2+ Web-based management\u003c\/li\u003e\n\u003cli\u003eQuality of Service (QoS) support Configuring Location Settings (CLI)\u003c\/li\u003e\n\u003cli\u003eBasic switching RJ-45 Ethernet ports quantity: 24 Console port: RJ-45\/Micro-USB\u003c\/li\u003e\n\u003cli\u003e10G support\u003c\/li\u003e\n\u003cli\u003eMAC address table: 16000 entries Switching capacity: 128 Gbit\/s\u003c\/li\u003e\n\u003cli\u003eAccess Control List (ACL)\u003c\/li\u003e\n\u003cli\u003e1U Rack mounting\u003c\/li\u003e\n\u003cli\u003eAC Power supply included Power over Ethernet (PoE)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003ctable style=\"width: 100%; display: block;\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManagement features\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"What switch device has, managed or unmanaged.\"\u003e\n\u003ctd\u003eSwitch type\u003c\/td\u003e\n\u003ctd\u003eManaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"A network switch is a computer networking device that links networking segments. A switch has different layers, such as layer 2 (a network bridge, operating at the data link layer, interconnecting a small number of devices) and layer 4 (can act as a firewall, amongst other things).\"\u003e\n\u003ctd\u003eSwitch layer\u003c\/td\u003e\n\u003ctd\u003eL2+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports Quality of Service (QoS) to prioritize specific network traffic to ensure performance for critical applications.\"\u003e\n\u003ctd\u003eQuality of Service (QoS) support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Using a website\/web application to manage something.\"\u003e\n\u003ctd\u003eWeb-based management\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device can be remotely configured, monitored, and managed via a cloud-based platform.\"\u003e\n\u003ctd\u003eCloud-managed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports Dynamic ARP Inspection to prevent ARP spoofing attacks by validating Address Resolution Protocol packets.\"\u003e\n\u003ctd\u003eARP inspection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether location settings can be configured via the command line interface (CLI).\"\u003e\n\u003ctd\u003eConfiguring Location Settings (CLI)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device maintains a record of internal system events and status changes for diagnostic purposes.\"\u003e\n\u003ctd\u003eSystem event log\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePorts \u0026amp; interfaces\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of basic switching RJ-45 Ethernet ports (sockets).\"\u003e\n\u003ctd\u003eBasic switching RJ-45 Ethernet ports quantity\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type\/category of basic switching RJ-45 Ethernet ports (sockets).\"\u003e\n\u003ctd\u003eBasic switching RJ-45 Ethernet ports type\u003c\/td\u003e\n\u003ctd\u003eGigabit Ethernet (10\/100\/1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The total number of available slots for inserting SFP+ transceiver modules to provide high-speed fiber optic or copper connectivity.\"\u003e\n\u003ctd\u003eSFP+ module slots quantity\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type of physical connector used for the management or console interface of the device (e.g. RJ-45 or USB).\"\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ-45\/Micro-USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type of electrical interface used to provide power to the network switch, such as a C13 socket or a DC-in jack.\"\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003eAC-in jack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eNetwork\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The way in which the network is working, e.g. IEEE 802.11a, IEEE 802.11b, IEEE 802.11g.\"\u003e\n\u003ctd\u003eNetworking standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3af, IEEE 802.3at\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The product can use Oracle 10G, which is a database management system introduced in 2003.\"\u003e\n\u003ctd\u003e10G support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the network switch can copy traffic from one or more ports to another port for monitoring and analysis purposes.\"\u003e\n\u003ctd\u003ePort mirroring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports the management of data transmission rates to prevent buffer overflow.\"\u003e\n\u003ctd\u003eFlow control support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports combining multiple network connections into a single logical link to increase throughput and provide redundancy.\"\u003e\n\u003ctd\u003eLink aggregation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device can monitor and limit the amount of broadcast traffic to prevent network congestion and potential crashes.\"\u003e\n\u003ctd\u003eBroadcast storm control\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device can control the maximum amount of network traffic allowed to pass through a specific port or interface to prevent congestion.\"\u003e\n\u003ctd\u003eRate limiting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports a network protocol that prevents loops in a bridge network topology.\"\u003e\n\u003ctd\u003eSpanning tree protocol\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device is susceptible to a performance degradation where a queue is blocked by a packet at the front of the line.\"\u003e\n\u003ctd\u003eHead-of-line (HOL) blocking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"A Virtual Local Area Network (VLAN) consists of a group of computers and switches that can be physically distributed over different networks and buildings, but form one LAN on a logical level.\"\u003e\n\u003ctd\u003eVLAN support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eData transmission\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The data transfer capacity of the switch per second.\"\u003e\n\u003ctd\u003eSwitching capacity\u003c\/td\u003e\n\u003ctd\u003e128 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of packets the device can process and send per second, measured in millions of packets per second (e.g., 148.8 Mpps).\"\u003e\n\u003ctd\u003eForwarding rate\u003c\/td\u003e\n\u003ctd\u003e95.23 Mpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The MAC address is the \" media access control address it is a unique given to network interface controller in device. mac table shows the addresses format.\u003e\n\u003ctd\u003eMAC address table\u003c\/td\u003e\n\u003ctd\u003e16000 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device buffers the entire incoming packet to verify its integrity before forwarding it to the destination.\"\u003e\n\u003ctd\u003eStore-and-forward\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports Ethernet frames with a payload larger than the standard 1500 bytes to increase data transfer efficiency.\"\u003e\n\u003ctd\u003eJumbo frames support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates the support for Ethernet frames larger than the standard 1500 bytes to increase data transfer efficiency (e.g. 9000 bytes).\"\u003e\n\u003ctd\u003eJumbo frames\u003c\/td\u003e\n\u003ctd\u003e9000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The amount of memory available in the network switch to temporarily store data packets during congestion, typically measured in megabytes (MB) or kilobytes (KB).\"\u003e\n\u003ctd\u003ePacket buffer memory\u003c\/td\u003e\n\u003ctd\u003e12 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSecurity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Specifies the supported Dynamic Host Configuration Protocol (DHCP) options for network configuration, such as DHCP Option 66 for boot server addresses.\"\u003e\n\u003ctd\u003eDHCP features\u003c\/td\u003e\n\u003ctd\u003eDHCP client, DHCP relay, DHCP server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports the definition of rules to filter network traffic and manage access permissions based on specific criteria.\"\u003e\n\u003ctd\u003eAccess Control List (ACL)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device can optimize multicast traffic by ensuring it is only forwarded to the ports that have requested it.\"\u003e\n\u003ctd\u003eIGMP snooping\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Security access control method whereby the 48-bit address assigned to each network card is used to determine access to the network. MAC addresses are uniquely assigned to each card, so using MAC filtering on a network permits and denies network access to specific devices through the use of blacklists and whitelists.\"\u003e\n\u003ctd\u003eMAC address filtering\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports the manual configuration of specific MAC addresses to secure a network port.\"\u003e\n\u003ctd\u003eStatic port security\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports secure remote management via SSH or SSL protocols.\"\u003e\n\u003ctd\u003eSSH\/SSL support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports Bridge Protocol Data Unit (BPDU) filtering or protection to prevent network loops and enhance security.\"\u003e\n\u003ctd\u003eBPDU filtering\/protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device can link a specific IP address and MAC address to a physical port to enhance network security and prevent unauthorized access.\"\u003e\n\u003ctd\u003eIP-MAC-Port binding\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The method used to verify the identity of a user or device before granting network access (e.g., MAC authentication or Captive portal).\"\u003e\n\u003ctd\u003eAuthentication\u003c\/td\u003e\n\u003ctd\u003eAuto VLAN, Guest VLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMulticast features\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device supports the simultaneous transmission of a single data stream to multiple recipients.\"\u003e\n\u003ctd\u003eMulticast support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDesign\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The type of mounting that can position devices in a shelving system (rack).\"\u003e\n\u003ctd\u003eRack mounting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The shape or design of the product.\"\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The colour e.g. red, blue, green, black, white.\"\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Indicates whether the device features a dedicated button to restore the unit to its original factory settings.\"\u003e\n\u003ctd\u003eReset button\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).\"\u003e\n\u003ctd\u003eLED indicators\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The quantity of fans (apparatus with rotating blades that creates a current of air for cooling or ventilation).\"\u003e\n\u003ctd\u003eNumber of fans\u003c\/td\u003e\n\u003ctd\u003e3 fan(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"What is providing power for the product e.g. mains electricity.\"\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"There is a power supply with this product.\"\u003e\n\u003ctd\u003ePower supply included\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The voltage of the AC electricity that is inputted into the product.\"\u003e\n\u003ctd\u003eAC input voltage\u003c\/td\u003e\n\u003ctd\u003e100 - 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).\"\u003e\n\u003ctd\u003eAC input frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum amount of power used by the device.\"\u003e\n\u003ctd\u003ePower consumption (max)\u003c\/td\u003e\n\u003ctd\u003e486.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower over Ethernet (PoE)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The device supports Power over Ethernet (PoE), which is one of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras.\"\u003e\n\u003ctd\u003ePower over Ethernet (PoE)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of network ports on the switch that can provide power to connected devices using the PoE+ standard.\"\u003e\n\u003ctd\u003ePower over Ethernet plus (PoE+) ports quantity\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The number of network switch ports that support the 4PPoE (PoE++) standard to provide high-power electricity to connected devices.\"\u003e\n\u003ctd\u003ePower over Ethernet 4PPoE (PoE++) ports quantity\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum amount of electrical power the network switch can deliver to a connected device per port, measured in Watts.\"\u003e\n\u003ctd\u003ePower over Ethernet (PoE) power per port\u003c\/td\u003e\n\u003ctd\u003e30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The maximum total amount of power available to be distributed across all PoE-enabled ports, measured in Watts (e.g. 120W).\"\u003e\n\u003ctd\u003eTotal Power over Ethernet (PoE) budget\u003c\/td\u003e\n\u003ctd\u003e500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperational conditions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The minimum and maximum temperatures at which the product can be safely operated.\"\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The minimum and maximum temperatures at which the product can be safely stored.\"\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-40 - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.\"\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e10 - 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.\"\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The heat generated by the power supply.\"\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e1658.78 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeight \u0026amp; dimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The measurement or extent of something from side to side.\"\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e440 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The distance from the front to the back of something.\"\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e330 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"The measurement of the product from head to foot or from base to top.\"\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePackaging content\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Specifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).\"\u003e\n\u003ctd\u003eCables included\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Instructions, either online, as a computer program or in paper form, to allow you to set up and start using the product quickly.\"\u003e\n\u003ctd\u003eQuick start guide\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCertificates\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr title=\"Specifies the official standards, safety approvals, or regulatory certifications the product has received.\"\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE, FCC, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"TP-Link","offers":[{"title":"Default Title","offer_id":67983915548715,"sku":"10392714","price":511.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0561\/2408\/0171\/files\/a55d622c4ae05cce8b851b3ba469dc896cf71be2.jpg?v=1792724374","url":"https:\/\/store.itcode.co.uk\/products\/auto-tp-link-omada-sg3428xmpp-v1-8-switch-l2-managed-16-x-10-100-1000-poe-8-x-10-100-1000-poe-4-x-10gb-ethernet-sfp-rack-mountable-poe-500-w","provider":"IT Code Store","version":"1.0","type":"link"}